a

Window Replacement Systems – Kalwall

Retrofits with Kalwall vs. Glass results in dramatic savings for stopping heat loss, reducing electric light usage by offering glare free-usable diffuse daylight, eliminating the need for shades, and decreasing solar heat gain. Our high performance systems are very competitively priced, virtually maintenance free, and offer increased security compared to typical glass retrofits, for both increased impact resistance and vandalism.

Technical Information

Savings from retrofitting with Kalwall -the most highly insulated light transmitting fenestration system on the market, can exceed 400% vs. standard glazing systems.

Before Window Replacement
Old, drafty single-pane glazing produced excessive glare and inhibited learning.
After Window Replacement
Energy-efficient Kalwall system creates a comfortable and protective classroom
Thermally Broken Wall Systems | 2-3/4" (70mm) Standard Thickness
For more demanding climate zones and building types. Thermally-Broken Wall systems provide enhanced envelope performance to meet or exceed the toughest energy codes.
Thermally-broken, interlocking I-beam panel grid core
Thermally-broken aluminum Clamp-tite™ fastening system
U-factors range from 0.23 - 0.05 (1.31 to 0.28 W/㎡K)
Solar Heat Gain Coefficients (SHGC) from 0.36 to 0.04
Visible Light Transmission (VLT) values from 3% to 35%
THERMAL BREAK+STRUCT SYSTEM | BACK FASTENED SYSTEM | CONCEALED FASTENERS | KALWALL 100 (4" SYSTEM)
Standard Wall Systems | 2-3/4" (70mm) Standard Thickness
For certain climate zones and building types, non thermally-broken Wall Systems provide sufficient envelope performance that is both cost effective and meets energy codes.
Standard, aluminum interlocking I-beam panel grid core
Standard aluminum Clamp-tite™ fastening system
U-factors range from 0.53 - 0.18 (3.01 to 1.02 W/㎡K)
Solar Heat Gain Coefficients (SHGC) from 0.65 to 0.10
Visible Light Transmission (VLT) values from 3% to 58%
STANDARD SYSTEM | BACK FASTENED SYSTEM | CONCEALED FASTENERS | KALCURVE | 1-9/16" SYSTEM
Specialty Applications | 2-3/4" (70mm) Standard Thickness
Kalwall offers many product configurations for projects that require special performance criteria to protect from extreme weather events and manage human safety+security
Class A fire ratings available for Wall Systems and Unitized Curtain Walls
Windborne debris protection - tested and certified up to large missile D
Blast resistant systems meet DOD UFC 4-010-01 anti-terrorism force protection
Factory Mutual certified systems: Class I exterior wall FM 4880 & FM 4881
Factory Mutual explosion venting pressure realease systems: FM 4440
WINDBORNE DEBRIS PROTECTION | EXPLOSION VENTING | ANTI-TERRORISM FORCE PROTECTION | FM CLASS I