a

Syntegra – XT Series

Flush Exit Device Openings

The flagship of Syntégra’s integrated door systems is the XT Series, which combines the functionality of a mortise lockset with the free-egress safety features of an exit device.

Building owners no longer have to sacrifice aesthetics for strength and durability because Syntégra engineers their door systems to be configurable and adaptable to meet the needs of the each opening. Finally, a ‘no compromise’ solution that looks as great as it performs.

The sleek yet balanced near-flush exit device recesses into the door face to maximize the clear opening width for a safe and accessible path of egress while complying with the strictest fire and life safety codes. Plus, the robust mechanisms and electrical functions are engineered to meet the most demanding and punishing commercial, educational, institutional, and industrial environments.

Single doors, pairs and double egress pairs found in the following applications:
    • Areas of assembly – arenas, ballrooms, houses of worship, performing arts, recreation facilities and restaurants
    • Areas of refuge – elevator lobbies and stairwells
    • Areas of separation – cross corridor
    • Paths of egress – building exits and ground floor stairwells

Benefits

Tested Durability
    • Heavy-wall aluminum construction
    • Pushbar holds retracted when the door is in the open position, maximizing the clear opening width and limiting damage
Enhanced Security
    • Patented friction-limiting latch bolt with 7/8″ throw
    • Available in top latching or top and bottom latching
    • Exterior lever with anti-abuse clutching
    • Protected latches and operating mechanisms are concealed within the steel door and sheltered from attack, abuse, or tampering
Versatility
    • Extensive list of ANSI functions to suit most openings and applications
    • Access control ready with latch retraction, electrified lever and RX options
    • Electrical options available in kit-form allowing for future upgrades
Uncompromised Safety
    • Listed for flush Panic Hardware (UL305) and for fire tests (UL10C) with single-point top latching or top and bottom latching
    • Pushbar holds retracted when the door is in the open position maximizing the clear opening
    • Top latching instead of side edge latchbolt and strike for singles and pairs prevents catching on clothing or equipment
    • Optional antimicrobial coatings available for healthcare, education and other germ-sensitive environments
    • CleanVue – Simple hygienic release feature allows for full access to the pushbar for sanitizing without disassembly
Unequaled Aesthetics
    • Minimized pushbar end caps with hidden fasteners provides clean, uninterrupted lines
    • Pushbar available in architectural and décor-matching finishes
    • Escutcheon-free levers available in the most popular styles and finishes
    • Décor Series levers used to make a unique design statement, or to match other locksets used on a project
    • Optional integrated top strike prep eliminates the need for a surface mounted auxiliary plate
    • Projection type latchbolt minimizes the top strike view and minimizes the top door “notch” required by others
    • No floor strikes required means fire ratings without the need for bottom latchbolts
Model Number
XT
XT-LC
XT-LC
XT-LC
XT-LC2
XT-C
XT-L
ANSI Function Description
01
03
08
09
10
13
14
Description
Exit Only, no trim.
Entrance by fixed lever/pull - latch released by key. Key removable when locked (Nightlatch).
Entrance by lever. Key locks or unlocks lever.
Entrance by lever. Key removable when locked (Nightlatch).
Entrance by lever. Inside or outside key locks or unlocks lever. Outside key releases latch.
Entrance by key.
Entrance by lever. Always active, no cylinder.

CLIQUEZ POUR VOIR LE PORTEFEUILLE

Lever options

If our standard levers don’t match your style preferences please ask about our Décor Lever Series.

Hardware Finish Options

Antimicrobial coatings are available for healthcare, education and other germ sensitive environments.

Hardware Specifications

Device Functions
Fire Ratings
Pushbar Height
Pushbar Width
Pushbar Projection - Extended
Pushbar Projection - Depressed or with Door Held Open
Pushbar Centerline
Pushbar Materials
Strikes
Electrical Options
Mounting
Latchbolts
Optional Keyed Cylinder
Function 10 - Back-to-back Cylinders
Configured from the factory. See Function Chart for description.
Listed for Panic Hardware (UL305) and for positive pressure fire tests (UL10C) with single-point top latching or top and bottom latching.
4”
15 ¼" (387 mm) for 24" to 29-15/16" openings | 18 ¼" (464 mm) for 30" to 35-15/16" openings | 24 ¼" (641 mm) for 36" to 41-15/16" openings | 30 ¼" (768 mm) for 42" to 51" openings
1-3/16" (30 mm)
3/16" (5 mm)
38-1/2" (978 mm) from structural floor (not including floor covering).
6063-T6 Extruded Aluminum with finish inserts.
Top strike can be mortised or surface applied (P/N TSK-1 Kit). Bottom strike, if applicable, is a ½” diameter hole threshold or surface strike (P/N BSK-1 Kit).
RX – Request to Exit. Provides a switch closure when the exit device is actuated. - RX2 – Same as above with two independent SPST switches.
ML - Motorized latch retraction quietly and efficiently retracts the latch(es) and pushbar when energized. Configured for fail-secure to comply to fire ratings.
LM - Latchbolt monitoring provides notification when the latch is extended.
ELS - Electrified lever. Energizing allows lever to rotate to retract the latch(es). Fail-Secure or Fail-Safe available.
Concealed fasteners on pushbar end caps, latches and handles.
Top latching standard with – 7/8" (22.2 mm) throw. Projection type - friction limiting-design with deadlatch feature. Bottom – Stainless Steel 5/8" throw bolt with conical tip.
Standard diameter Mortise Cylinder with 'standard' cam. Accepts 1" cylinder length or greater. Cylinder in excess of 1” requires a spacer collar equal to this excess (Example 1-1/8" length requires a 1/8" collar).
Requires a 3/16" collar for a 1" cylinder length. For longer cylinders, use the following to dimension the collar: Cylinder Length –1” + 3/16”= Collar (Ex. 1-1/4" requires a 7/16” collar).

VOUS AIMEZ CE QUE VOUS VOYEZ?

Communiquez avec nous pour des partenariats, de nouveaux projets et des demandes de renseignements.